A-02Y(L)2Y n x 2
Outdoor Telecommunication Cable According To DIN VDE 0816 Part 1
Reference Standard: A-02Y(L)2Y according to DIN VDE 0816 Part 1
Application:This cable is used in local telephone networks as subscriber cable
Conductor Material: Solid annealed copper conductor
Insulation Material:Foamed PE (02Y)
Laying-up: Star quads in unit stranding
Wrapping Polyester Tape
Screen Material: Aluminium Foil with copper drain wire
Sheath Material: PE
Sheath Color: Black
Temperature Range: Flexible: -20¡æ to +50¡æ fixed installation:- 40¡ãC to +70¡æ
Operating Voltage: 225V
Electrical Performance:
Conductor Diameter (mm) |
Insulation Resistance of per km at 20 o C
Min. (GOhms) |
Conductor Resistance per km loop
Max. (Ohms) |
0.6 |
1.5 |
100 |
0.8 |
1.5 |
73.2 |
0.9 |
10 |
56.6 |
Size & Dimensions:
A - 02Y(L)2Y ... x 2 x 0,6 STIII BD
Part No. |
No.of pairs |
Outerdiameter
£¨mm£© |
Cable Weight
£¨kg/km£© |
Copper Weight
(kg/km) |
CCL-TC-02Y6P0.6 |
6 |
12 |
130 |
34 |
CCL-TC-02Y10P0.6 |
10 |
13.5 |
170 |
57 |
CCL-TC-02Y20P0.6 |
20 |
16 |
260 |
113 |
CCL-TC-02Y30P0.6 |
30 |
18 |
340 |
170 |
CCL-TC-02Y40P0.6 |
40 |
20 |
420 |
226 |
CCL-TC-02Y50P0.6 |
50 |
21.5 |
490 |
283 |
CCL-TC-02Y70P0.6 |
70 |
24 |
650 |
396 |
CCL-TC-02Y100P0.6 |
100 |
28 |
880 |
565 |
CCL-TC-02Y150P0.6 |
150 |
33 |
1260 |
848 |
CCL-TC-02Y2006P0.6 |
200 |
37.5 |
1640 |
1131 |
A - 02Y(L)2Y ... x 2 x 0.8 STIII BD
Part No. |
No.of pairs |
Outer diameter
£¨mm£© |
Cable Weight
£¨kg/km£© |
Copper Weight
(kg/km) |
CCL-TC-02Y6P0.8 |
6 |
13 |
160 |
60 |
CCL-TC-02Y10P08 |
10 |
15 |
225 |
101 |
CCL-TC-02Y20P0.8 |
20 |
18.5 |
360 |
201 |
CCL-TC-02Y30P0.8 |
30 |
21 |
490 |
302 |
CCL-TC-02Y40P0.8 |
40 |
23.5 |
610 |
402 |
CCL-TC-02Y50P0.8 |
50 |
26 |
750 |
503 |
CCL-TC-02Y70P0.8 |
70 |
29.5 |
990 |
704 |
CCL-TC-02Y100P0.8 |
100 |
34 |
1350 |
1005 |
CCL-TC-02Y150P0.8 |
150 |
41 |
2020 |
1508 |
CCL-TC-02Y2006P0.8 |
200 |
47 |
2650 |
2011 |
website: www.caledonian-cables.com
email: sales@caledonian-cables.com
|